Spectrum Transmission Meter
Spectrum Transmission Meter
Spectrum Transmission Meter
Spectrum Transmission Meter
Spectrum Transmission Meter
Spectrum Transmission Meter
Spectrum Transmission Meter
Spectrum Transmission Meter

Spectrum Transmission Meter

Spectrum Transmission Meter Specification

  • Max Height
  • 100 mm
  • Specimen Size
  • Up to 50 mm width
  • Interface Type
  • Digital and USB
  • Temperature
  • 5C to 45C
  • Measuring Range
  • Visible/UV/IR Spectrum
  • Features
  • Automatic Zeroing, Simple Operation, Portable Design
  • Mounting Type
  • Bench-top
  • Gas Pressure
  • Ambient
  • Number of Specimens
  • 1
  • Port Size
  • Standard Optical Port
  • Response Time
  • <2 seconds
  • Operating Voltage
  • 110-240V
  • Power Supply
  • 110-240V AC, 50/60Hz
  • Automation Grade
  • Semi-Automatic
  • Test Range
  • 200 nm 2500 nm
  • Humidity
  • 0-90% RH
  • Resolution
  • 0.1 nm
  • Frequency
  • 50/60 Hz
  • Application
  • Spectral Transmission Measurement
  • Equipment Type
  • Transmission Meter
  • Display Type
  • Digital Display
  • Accuracy
  • 1%
  • Usage
  • Glass, Plastic & Film Transmission Testing
  • Capacity
  • Single Specimen Measurement
  • Machine Weight
  • Approx. 3.5 kg
  • Test Speed
  • Standard
  • Test Width
  • 50 mm
  • Test Stroke
  • Customizable
  • Control Mode
  • Manual
 
 

About Spectrum Transmission Meter

As a Authorized dealer we are engaged in providing wide gamut of optical instruments used in various applications.

It is able to simultaneously measure and display PLPurple Light, BL(Blue light) and VL(Visible Light) transmission values. This meter is self-contained light sources and self-calibration. No adjustment is needed. The users only need plug the power supply, turn on the switch and put the sample in the testing position. The resulting performance data appear on the display.

Specification :

  • Size: 200mm x 180mm x 106mm (LxWxH
  • Size of Testing sample: > 3mm
  • Weigh: 1500g
  • Resolution: 0.1%
  • Accuracy: 2%(Colorless and transparent material)
  • 6.Purple light Peak wavelength: 395nm
  • Blue light Peak wavelength: 460nm
  • Visible light Peak wavelength: 550nm
  • Power supply: 5V DC Adapter

Features:

  • PL transmission meter, BL transmission meter, Light Transmittance Meter, Three function in ONE device.
  • Self-calibration and auto-calibration, NO need any manual adjustments.
  • Simple operation, putting the testing sample in the testing position, PL, BL and VL transmission values of the sample will simultaneously display.


Advanced Transmission Measurement

The Spectrum Transmission Meter delivers reliable and repeatable spectral transmission analysis for glass, plastic, and film. Its combination of halogen and LED light sources, together with a high-resolution photodiode array sensor, makes it ideal for research, industrial quality control, and laboratory environments that require precise optical measurements.


User-Friendly Design and Operation

Designed for simplicity, the device features an adjustable clamp sample holder and manual control mode, facilitating easy specimen placement and operation. Automatic zeroing, digital display, and USB export further enhance its usability. Its bench-top, portable form factor is perfect for laboratories needing flexible yet robust equipment.


Reliable Performance and Safety

Factory calibration ensures consistent measurement accuracy, while overvoltage protection maintains operational safety. The powder-coated aluminum construction guarantees longevity even with regular use. Supported by a one-year warranty, this transmission meter prioritizes reliability and user peace of mind.

FAQs of Spectrum Transmission Meter:


Q: How do I use the Spectrum Transmission Meter for a measurement?

A: To measure spectral transmission, place your specimen (up to 10 mm thick, 50 mm wide) in the adjustable clamp holder. Select your preferred test stroke and initiate measurement using manual controls. Results are displayed digitally, with data easily exportable via USB.

Q: What types of materials can this transmission meter test?

A: This device is engineered for transmission testing of glass, plastic, and film specimens, making it suitable for diverse applications in research, development, and production quality assurance.

Q: When should I recalibrate the Spectrum Transmission Meter?

A: The unit is factory calibrated and does not require user recalibration under normal indoor conditions. For critical applications or after extensive use, periodic verification is recommended as per your laboratory protocols.

Q: Where can this meter be safely operated?

A: It is designed for indoor laboratory environments with ambient gas pressure, temperature between 5C to 45C, and humidity up to 90% RH. For optimal performance and safety, always operate it on a stable benchtop surface.

Q: What is the process for exporting measurement data?

A: After completing a test, simply connect the device to your computer using the provided USB interface. Measurement results are digitally transferred and can be archived or analyzed as needed.

Q: What are the main benefits of using this transmission meter?

A: Key advantages include high measurement accuracy (1%), rapid results (<2 seconds), broad spectral range (200 nm 2500 nm), automatic zeroing, and a portable, robust construction with safety features such as overvoltage protection.

Q: Can the test stroke and specimen size be customized?

A: Yes, the test stroke is customizable, and specimens up to 50 mm in width and 10 mm in thickness can be accommodated, providing flexibility for various testing requirements.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Optical Instrument Category

White Meter

White Meter

Accuracy : 0.5% F.S.

Display Type : Digital

Application : Material Testing, Textile, Laboratory

Automation Grade : Automatic

Response Time : Instantaneous

Usage : Laboratory, Industrial

Powder Whiteness Meter

Powder Whiteness Meter

Accuracy : 0.5

Display Type : Digital LED display

Application : Measurement of powder and granule whiteness

Automation Grade : Automatic

Response Time : 5 seconds

Usage : Whiteness measurement in powder technology

Double-Geo Haze Gloss Meter

Double-Geo Haze Gloss Meter

Accuracy : 1 GU (Gloss), 0.1% (Haze)

Display Type : Digital LCD

Application : Measurement of surface gloss and haze in coatings, plastics, and glass

Automation Grade : Manual

Response Time : 2 seconds

Usage : Surface gloss and haze evaluation

Portable Whiteness Meter

Portable Whiteness Meter

Accuracy : 1 Whiteness unit

Display Type : Digital LCD

Application : Paper, textile, plastics, chemical fiber, building materials

Automation Grade : Manual

Response Time : 2 seconds

Usage : Onsite whiteness measurement